Yaskawa MotionSuite Series Machine Controller Programming Manual de usuario Pagina 172

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 187
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 171
MotionSuite™ Series Machine Controller Motion Programming Manual Chapter 4: Sequence Commands
4-40
4.6.11 Designated Bit OFF (R{ })
!
!!
! Outline
The Designated Bit OFF (R{}) command turns a designated bit OFF if the Logical
Calculation result is true. However, it does not turn a designated bit OFF if the result is
false.
!
!!
! Detailed Explanation
Command Method
Data Type
$
= Yes × = No
!
!!
! Program Example
Bit (B) Integer (W) 32-bit Integer (L) Real (F) Constant
Designated Bit
$
××××
Logical Calculation Format
$$ $
×
$
Type Motion Program Ladder Program
B R{MB001000}=MB001010&MB001011
W—
L—
F—
R{MB001000}=MB001010&MB001011
AB
A: Designated bit
C: Logical Calculation format