MotionSuite™ Series Machine Controller Programming Manual Chapter 3: Advanced Programming Methods
3-45
! Program Examples
FMX T10000;
INC;
IAC T1000;
MVS [axis1] 100000 F70000;
IAC T500;
MVS [axis1] 100000;
Important Point
When designating the IAC command, set up the maximum interpolation feed speed in
advance with the FMX command, to avoid an error.
v
t
1000msec
500msec
Figure 3.25: Program Example of the Interpolation Acceleration Time Change
FM Set Speed
F Command Speed