Yaskawa VS-616G5 Series Revision F Programming Manual Manual de usuario Pagina 99

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 162
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 98
VS-616G5 Programming Manual 99
H4 Analog Outputs
The VS-616G5 has two analog outputs, for the external monitoring of drive conditions such as output
frequency, output current, PID feedback and others.
Selects the analog output monitors for terminal 21.
The resolution of terminal 21 is 9 bit plus sign.
Setting Range: 0.00 to 2.50
Factory Default: 1.00
Sets the terminal 21 output gain for the analog output monitors. To obtain the output level, multiply the
monitor output level by the gain value set in H4-02.
H4-01 Terminal 21 Analog Output Selection Terminal 21 Sel
B B B B
Setting Description
1 Frequency reference
2 Output frequency (factory default)
3 Inverter output current
5 Motor speed
6 Output voltage
7 DC bus voltage
8 Output power
9 Torque reference (internal)
15 Terminal 13 input voltage level
16 Terminal 14 input voltage or current level
17 Terminal 16 input voltage level
18 Motor secondary current (Iq)
19 Motor excitation current (Id)
20 SFS output frequency
21 ASR input
22 ASR output
23 Speed deviation
24 PID feedback
26 Voltage reference (Vq output)
27 Voltage reference (Vd output)
32 ACR (q) Output
33 ACR (d) Output
36 PID Input Monitor <1110>
37 PID Output Monitor<1110>
38 PID Setpoint Monitor <1110>
H4-02 Terminal 21 Analog Output Gain Terminal 21 Gain
B B B B
Section H: Control Circuit Terminals
H4 Analog Outputs