VS-616G5 Programming Manual 139
Group E Motor
Function E2 Motor Setup
E2-00
Motor Rated
(Motor Rated )
— — —
* When inverter capacity is
7.5 kW or less, min. setting
unit becomes 0.01 A.
** Factory setting differs
depending on inverter
capacity (02-04).
x - - - -
E2-01
Motor Rated
Current
(Motor Rated FLA)
0.1~
1500.0
0.1A* 1.9** x Q Q Q Q
E2-02
Motor Rated Slip
(Motor Rated Slip)
0.00~
20.00
0.01Hz 2.90** x A A Q Q
E2-03
Motor No-load
Current
(No-Load Current)
0.00~
1500.0
0.01A* 1.20** x A A Q Q
E2-04
Number of Motor
Poles
(Number of Poles)
2~48 1 pole 4 x - Q - Q
E2-05
Motor Line-to-line
Resistance
(Term Resistance)
0.000~
65.000
0.001
W
9.842** x A A A A
E2-06
Motor Leak
Inductance
(Leak Inductance)
0.0~
30.0
0.1% 18.2** x - - A A
E2-07
Motor Iron-core
Saturation Coeffi-
cient 1
(Saturation Comp
1)
0.00~
0.50
0.01 0.50 — x - - A A
E2-08
Motor Iron-core
Saturation Coeffi-
cient 2
(Saturation Comp
2)
0.00~
0.75
0.01 0.75 — x - - A A
E2-09
Motor Mechanical
Loss
(Mechanical Loss)
0.0~
10.0
0.1% 0.0 — x - - - A
E2-10
Motor Iron Loss of
Torque Compensa-
tion (Tcomp Iron
Loss)
0~
65535
1W 14
Access level is changed from
F to A. <1110>
x A A - -
Function
Parameter
No.
Name
(Digital Operator
Display)
Setting
Range
Setting
Unit
Factory
Setting
Remarks
(Digital Operator Display)
Change
during
Operation
o: Enabled
x: Disabled
Parameter Access Level
User
Setting
V/f
V/f
w/
PG
Open
Loop
Vector
Flux
Vector
Appendix
VS-616G5 Parameter List E Motor