4.3 Motion Parameter Lists
4.3.2 Setting Parameter List
4-11
Motion Parameters
OL0C
Torque/Thrust
Reference Setting
Unit is according to OW03, bits 12 to 15 (Torque Unit
Setting).
Yes Yes
4.4.2 ( 10 )
OW0E
Speed Limit Setting
at the Torque/Thrust
Reference
1 = 0.01% (percentage of rated speed)
Yes
OW0F
Reserved for system use.
−−
OL10
Speed Reference
Setting
Unit is according to OW03, bits 0 to 3 (Speed Unit
Selection).
Yes Yes 4.4.2 ( 11 )
OW12
to
OW13
Reserved for system use.
−−
OL14
Positive Side Limiting
Torque/Thrust Setting
at the Speed Refer-
ence
Unit is according to OW03, bits C to F (Torque Unit).
Yes 4.4.2 ( 12 )
OL16
Secondly Speed
Compensation
Unit is according to OW03, bits 0 to 3 (Speed Unit
Selection).
Yes Yes 4.4.2 ( 13 )
OW18
Override
1 = 0.01%
Yes 4.4.2 ( 14 )
OW19
to
OW1B
Reserved for system use.
−−
OL1C
Position Reference
Setting
1 = 1 reference unit
Yes Yes 4.4.2 ( 15 )
OL1E
Width of Positioning
Completion
1 = 1 reference unit
Yes 4.4.2 ( 16 )
OL20
NEAR Sign
al Output
Width
1 = 1 reference unit
Yes 4.4.2 ( 17 )
OL22
Error Count Alarm
Detection
1 = 1 reference unit
Yes 4.4.2 ( 18 )
OL24
Reserved for system use.
−−
OW26
Positioning
Completion Check
Time
1 = 1 ms
Yes 4.4.2 ( 19 )
OW27
Reserved for system use.
−−
OL28
Phase Correction
Setting
1 = 1 reference unit
Yes 4.4.2 ( 20 )
OL2A
Latch Zone Lower
Limit Setting
1 = 1 reference unit
Yes
4.4.2 ( 21 )
OL2C
Latch Zone Upper
Limit Setting
1 = 1 reference unit
Yes
OW2E
Position Loop Gain
1 = 0.1/s
Yes
4.4.2 ( 22 )
OW2F
Speed Loop Gain
1 = 1 Hz
Yes
OW30
Speed Feedforward
Amends
1 = 0.01% (percentage of distribution segment)
Yes
OW31
Speed
Compensation
1 = 0.01% (percentage of rated speed)
Yes Yes
OW32
Position Integration
Time Constant
1 = 1 ms
Yes
OW33
Reserved
for system use.
−−
OW34
S
peed Integration
Time Constant
1 = 0.01 ms
Yes 4.4.2 ( 22 )
OW35
Reserved for system use.
−−
(cont’d)