2.1 LED Indicators and Switch Settings
2.1.4 Switch Settings
2-5
Settings and Installation
( 2 ) Rotary Switches
This rotary switch is valid only in Slave Mode.
It will be ignored in Master Mode.
Name Status Operating Mode
Default
Setting
Details
×10
0 to 9
Local address in Slave Mode
(Tens digit)
0
Set the tens digit of the local slave address.
Example: Turn to “1” for the address, 15.
×1
0 to 9
Local address in Slave Mode
(Ones digit)
1
Set the ones digit of the local slave address.
Example: Turn to “5” for the address, 15.
10
1