Yaskawa MP2000 Series I/O Module User Manual Manual de usuario Pagina 61

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 139
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 60
2.5 Electronic Gear Function
2.5.3 Electronic Gear Setting Examples
61
2
LIO-01/LIO-02 Module
2.5.3 Electronic Gear Setting Examples
The following is setting examples for each kind of load mechanical configuration.
( 1 ) Example A: Ball Screw
In the above machine system, if the reference unit = 0.001 mm, the setting of each parameter will be as follows:
Moving Amount Per Machine Rotation
= 6 mm/0.001 mm = 6000
• Counter fixed parameter No. 11 (Encoder Gear Ratio) =
7
(rotations)
• Counter fixed parameter No. 12 (Machine Gear Ratio) =
5
(rotations)
( 2 ) Example B: Rotating Load
In the above machine system, if the reference unit = 0.1°, the setting of each parameter will be as follows:
• Moving Amount Per Machine Rotation = 360°/0.1° = 3600
• Counter fixed parameter No. 11 (Encoder Gear Ratio) =
3
(rotations)
• Counter fixed parameter No. 12 (Machine
Gear Ratio
) =
1
(rotation)
m7 rotations
n5 rotations
Ball screw pitch
P6mm/rotation
Encoder
Rotating load
360°/rotation
Encoder
m30 rotations
n10 rotations
Vista de pagina 60
1 2 ... 56 57 58 59 60 61 62 63 64 65 66 ... 138 139

Comentarios a estos manuales

Sin comentarios