106 VS-616PS5 Programming Manual
F1-04 PG deviation detection stopping method
0: Ramp to Stop 2: Fast-Stop
1: Coast to Stop 3: Alarm Only
- 0~3 3 B
F1-05 PG rotation selection
0: CCW 1: CW
- 0/1 1 Q
F1-08 Overspeed detection level % 0~120 115 A
F1-09 Overspeed detection time s 0~2.0 0.0 A
F1-10 PG deviation detection level % 0~50 10 A
F1-11 PG deviation detection time s 0~10.0 0.5 A
F1-13 PG open phase detection delay time s 0.0~10.0 3.0 A
F2 A1-14B Setup
F2-01 Bipolar or unipolar input selection
0: 3-channel individual 1: 3-channel additional
- 0/1 0 A
F3 D1-08/DI-16H Setup
F3-01 Digital input option
0: BCD 1% 2: BCD 0.01%
1: BCD 0.1% 7: Binary
- 0~7 0 A
F4 AO-08/AO-12 Setup
F4-01 Analog output Channel 1 selection
1: Speed reference
2: Output frequency
3: Inverter output current
5: Motor speed
6: Output voltage
7: DC bus voltage
8: Output power
9: Torque reference (internal)
15: External terminal 13 input voltage
16: External terminal 14 input voltage
17: External terminal 16 input voltage
18: Motor secondary current (I
q
)
19: Motor excitation current (I
d
)
20: Primary frequency after SFS
21: Speed controller ASR input
22: Speed controller ASR output
27: q Axis current control reference
28: d Axis current control reference
29: Voltage limit control output
30: q Axis current control output
31: d Axis current control output
32: Output voltage reference (V
q
)
33: Output voltage reference (V
d
)
45: External torque reference
46: Torque compensation value
49: Control section software number
50: Speed detection PG counter value
53: PID feedback
- 1~60 5 A
F4-02 Analog output channel 1 gain - ±300.0 1.0 A
F4-03 Analog output channel 1 bias % ±109.2 0.0 A
F4-04 Analog output channel 2 selection
(same as F4-01)
- 1~60 3 A
F4-05 Analog output channel 2 gain - ±300.0 1.0 A
No. Parameter Description Unit Setting Range Default
Access
Level
User
Setting
Appendix
VS-616PS5 Parameter List
Comentarios a estos manuales