2.2 Basic Module
2.2.5 Built-in SVB Module
2-33
Specifications and Functions
[ e ] Synchronization between Modules
1. Overview
MP2300S Machine Controller has a function that can synchronize hardware between the CPU and an optional
module. This function enables MECHATROLINK communications in synchronization with high-speed scans.
As a result, synchronization between a built-in SVB Module and an SVB-01 Module, or among multiple SVB-01
Modules, can be enabled.
When synchronized mode is used, the start of the high-speed scan and the various communication cycles are syn-
chronized. This means that commands from the high-speed scan will be sent at consistent points in communica-
tion cycle processing and simplifies distribution processing for interpolation commands.
2. Conditions Under Which Synchronization Is Possible
The following table shows the combinations of high-speed scan times and MECHATROLINK communication
cycles that allow synchronization between modules in the synchronization mode.
High-speed Scan
(RTC: 0.5 ms)
MECHATROLINK Communication Cycle
0.5 ms 1 ms 1.5 ms 2 ms
1.0 ms
Yes Yes Yes
1.5 ms
Yes Ye s
2.0 ms
Yes Yes Yes
2.5 ms
Yes −−−
3.0 ms
Yes Yes Yes
3.5 ms
Yes −−−
4.0 ms
Yes Yes Yes
4.5 ms
Yes Ye s
5.0 ms
Yes Yes −−
5.5 ms
Yes −−−
6.0 ms
Yes Yes Yes Ye s
:
High-speed scan
4 ms
2 ms
1 ms
2 ms
Communication
cycle for SVB built
into the CPU
Communication
cycle for SVB-01
#1
Communication
cycle for SVB-01
#2