Yaskawa MP2300S Basic Module Manual de usuario Pagina 346

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 460
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 345
Appendix B SERVOPACK Parameter Data Flow
B.1 Operations and Parameter Data Flow
A-24
( 5 ) Copying Current Values to Set Values (Input Data) in the SERVOPACK Tab
The data flow for SERVOPACK parameters is as follows when selecting Edit - Copy Current Value from the SERVO-
PACK Tab in the SVB Definition Window on the MPE720:
1. The MPE720 copies the values currently displayed in Current Value to Input Data on the SERVO-
PACK Tab and displays.
MECHATROLINK
RAM
EEP
-ROM
SRAM
SDRAM
MP2300S
SERVOPACKSERVOPACK
Control
Software
System
Software
Parameters
Servo Parameters
(All Axes)
Flash
Memory
Input
Data
MPE720 online
HDD in personal computer
Display
Current
Value
Input
Data
Vista de pagina 345
1 2 ... 341 342 343 344 345 346 347 348 349 350 351 ... 459 460

Comentarios a estos manuales

Sin comentarios