2.2 Basic Module
2.2.4 218IFA Module (Ethernet)
2-21
Specifications and Functions
Code
ASCII
BIN
RTU
Select a code type for the message communication data.
Depending on protocol type, available codes are restricted as fol-
lows:
: Available, – : Not available
ASCII
Automatically
Opens the automatic receive setting screen. To open the screen,
double-click this button.
Note: The automatic receive function is valid only for a connection
when the connection number = 1.
Remote
Station Name
Up to 32 single-
byte characters
(16 double-byte
characters)
Any text can be entered as a connection comment.
Blank
Item Setting Range Details Default
Protocol Type
Code
ASCII BIN RTU
Extended
MEMOBUS
√√
MEMOBUS
MELSEC
√√
Non-procedure
√√
MODBUS/TCP