6.2 Communication with Other MP Series
6.2.1 When the MP2300S Acts as Slave (automatic receive function is used)
6-10
e Set Subnet Mask (“255.255.255.000,” for example).
f Set Gateway IP Address (“000.000.000.000,” for example).
Caution
Set up a unique IP address in the network.
For the IP address, check with your network administrator.
3. Set connection parameters.
How to set up with a connection number 01 in the connection parameter setting screen
c Set Local Port to the port number used in the MP2300 side (“10001,” for example).
d Set Node IP Address to the IP address configured in the MP2300S side.
e Set Node Port to the port number configured in the MP2300S side (“10001,” for example).
f Select Connect Type (TCP, for example).
g Select Extended MEMOBUS for Protocol Type.
h Select Code (BIN, for example).
Caution
When any transmission or connection parameter is changed, the change will be reflected after FLASH has been saved and the
power turned ON again.