3.2 Commands Details
3-17
3
Commands for Preparation Process
3.2.9 Turn Encoder Power Supply ON (SENS_ON: 23H)
Send SENS_ON command to turn ON the encoder power supply.
(1) SENS_ON Command (23H)
The specifications of the SENS_ON command are described below.
(2) Monitor Selection Field Specifications: SEL_MON1/2/3/4
The monitor selection (SEL_MON1/2/3/4) field is used to select the Servo monitor information.
Applicable Commands:
SV_ON, SV_OFF, HOLD, INTERPOLATE, POSING, FEED, LATCH, EX_POSING, ZRET, VELCTRL,
TRQCTRL, SMON, SENS_ON, SENS_OFF, BRK_ON, BRK_OFF, LTMOD_ON, LTMOD_OFF
Setting Method:
Set MONITOR 1/2/3/4 monitor codes in SEL_MON1/2/3/4 allocated in the thirteenth byte of the main com-
mand or in the reserved area of the nineteenth byte of the subcommand.
SEL_MON1/2/3/4 allocation is shown below.
Byte
SENS_ON
Description
Command Response
1 23H 23H
Phases in
which the
command can
be executed
Phase 2 and 3
Synchronization
classification
Asynchronous
command
2ALARM
Processing
time
Within 2 s
Subcommand Cannot be used
3
STATUS
Obtains the initial position data and creates the present position when an
absolute encoder is used.
The reference point, home position (ZPOINT), and software limits will
be enabled when an absolute encoder is used.
After having used this command, the position data must be monitored
and the coordinate system of host controller must be setup.
4
5
MONITOR1
6
7
8
9
MONITOR2
10
11
12
13 SEL_MON1/2 SEL_MON1/2
14
IO_MON
15
16 WDT RWDT
D7 D6 D5 D4 D3 D2 D1 D0
SEL_MON2 SEL_MON1
D7 D6 D5 D4 D3 D2 D1 D0
SEL_MON4 SEL_MON3
Vista de pagina 47