5.2 Command Related Parameters Details
5-23
5
Command Related Parameters
(2) I/O Monitor Field Signal Allocation
Allocate CN1 connector input signals to bits D12 to D15 of the I/O monitor field.
When the Σ-V Series SERVOPACKs (SGDV-A11, -A15, -D11,
-D15, -F11, -F15) are Used
When the DC Power Input Σ-V Series SERVOPACKs (SGDV-E11) are Used
When the Large-Capacity Σ-V Series SERVOPACKs (SGDV-H11, -J11) are
Used
Parameter
Function Setting Allocation
Factory
Setting
No. Digit
Pn81E
0 IO12 Signal Mapping
0 No mapping
0
1 Monitors the CN1-13 input terminal
2 Monitors the CN1-7 input terminal
3 Monitors the CN1-8 input terminal
4 Monitors the CN1-9 input terminal
5 Monitors the CN1-10 input terminal
6 Monitors the CN1-11 input terminal
7 Monitors the CN1-12 input terminal
1 IO13 Signal Mapping 1 to 7 Refer to IO12 signal mapping 0
2 IO14 Signal Mapping 1 to 7 Refer to IO12 signal mapping 0
3 IO15 Signal Mapping 1 to 7 Refer to IO12 signal mapping 0
Parameter
Function Setting Allocation
Factory
Setting
No. Digit
Pn81E
0 IO12 Signal Mapping
0 No mapping
0
1 Monitors the CN1-7 input terminal
2 Monitors the CN1-3 input terminal
3 Monitors the CN1-8 input terminal
4 No mapping
5 No mapping
6 No mapping
7 No mapping
1 IO13 Signal Mapping 1 to 7 Refer to IO12 signal mapping 0
2 IO14 Signal Mapping 1 to 7 Refer to IO12 signal mapping 0
3 IO15 Signal Mapping 1 to 7 Refer to IO12 signal mapping 0
Parameter
Function Setting Allocation
Factory
Setting
No. Digit
Pn81E
0 IO12 Signal Mapping
0 No mapping
0
1 Monitors the CN1-40 input terminal
2 Monitors the CN1-41 input terminal
3 Monitors the CN1-42 input terminal
4 Monitors the CN1-43 input terminal
5 Monitors the CN1-44 input terminal
6 Monitors the CN1-45 input terminal
7 Monitors the CN1-46 input terminal
1 IO13 Signal Mapping 1 to 7 Refer to IO12 signal mapping 0
2 IO14 Signal Mapping 1 to 7 Refer to IO12 signal mapping 0
3 IO15 Signal Mapping 1 to 7 Refer to IO12 signal mapping 0