5 Command Related Parameters
5.2.7 STATUS Field and Monitor Related Settings
5-24
(3) Option Monitor Setting
Set the contents to be monitored when Option Monitor 1 and Option Monitor 2 are selected for MONITOR 1/
2/3/4.
Can only be set for Σ-V Series SERVOPACKs model SGDV-B.
Parameter
No.
Name Remarks
Pn824
Option Monitor 1 Selection
0000H Motor rotation speed [1000000H/OS]
0001H Speed reference [1000000H/OS]
0002H Torque (Force) [1000000H/max. torque (force)]
0003H Position error (lowermost 32 bits) [reference unit]
0004H Position error (uppermost 32 bits) [reference unit]
0005H System reserved
0006H System reserved
000AH Encoder count (lowermost 32 bits) [reference unit]
000BH Encoder count (uppermost 32 bits) [reference unit]
000CH
External encoder count (lowermost 32 bits) [reference
unit]
For fully-closed loop control
000DH
External encoder count (uppermost 32 bits) [reference
unit]
For fully-closed loop control
0010H Un000: Motor rotation speed [min
-1
]–
0011H Un001: Speed reference [min
-1
]–
0012H Un002: Torque (Force) reference [%]
0013H Un003: Rotation angle 1 [pulse]
0014H Un004: Rotation angle 2 [degree]
0015H Un005: Input signal monitor
0016H Un006: Output signal monitor
0017H Un007: Input position reference speed [min
-1
]–
0018H Un008: Position error [reference unit]
0019H Un009: Accumulated load ratio [%]
001AH Un00A: Regenerative load ratio [%]
001BH Un00B: DB resistance consumption power [%]
001CH Un00C: Input reference pulse [reference unit]
001DH Un00D: Feedback pulse [pulse]
001EH Un00E: Fully-closed loop feedback pulse [pulse] For fully-closed loop control
0023H Initial multiturn data [rev] For rotational servomotors
0024H Initial incremental pulse For rotational servomotors
0025H Initial absolute position data lowermost 32 bits [pulse] For linear servomotors
0026H Initial absolute position data uppermost 32 bits [pulse] For linear servomotors
0027H
*
Un022: Installation environment monitor [%]
0080H Previous value of latched feedback position (LPOS)
Others Reserved parameters (Do not use.)
Pn825 Option Monitor 2 Selection (Same as for Pn824)