7 Data Field
7.1.2 OPTION Field Specifications
7-4
7.1.2 OPTION Field Specifications
The option field is used to add functions to a motion command.
(1) Applicable Commands
SV_ON, HOLD, INTERPOLATE, POSING, FEED, LATCH, EX_POSING, ZRET, VELCTRL, TRQCTRL,
SVCTRL
Set the functions to be added to a motion command in the main command third and forth bytes reserved for the
option field.
The option field of the Σ-V series SERVOPACK is set by default as shown below.
To change the default setting, set the parameter Pn81F as Pn81F = 1, and set the bits to which functions
are to be allocated using the parameters Pn82A to Pn82E. The change must be validated by turning the power
supply OFF and then ON again or by sending a CONFIG command.
(2) OPTION Field Default Setting
D7 D6 D5 D4 D3 D2 D1 D0
000 ACCFIL 000
D15 D14 D13 D12 D11 D10 D9 D8
N_CL P_CL P_PI_CLR V_PPI 0 0 G_SEL