YASKAWA TM.iQp.07 iQpump Controller Programming Manual 187
Figure 1.136
Figure 140.
Figure 1.137
Figure 141.
TIME
Feedback
Multi-function
Input #84
0 Hz
Pre-Charge Freq.
P4-02
Pre-Charge Completed
Chart : Pre- Charge ,
Turn Off Feedback Level
Disable Pre-Charge, Contact Open
Pre-Charge Lvl.
P4-01
Stop Drive Run Pre-Charge Mode Auto Mode Operation
Run
TIME
Input Closed
Multi-function
Input #84
0 Hz
Pre-Charge Freq.
P4-02
Pre-Charge Completed
Chart: Pre-Charge,
Turn Off Low Water Input
Low Water Input
#85 Active
Stop Drive Run Pre-Charge Mode Auto Mode Operation
Run
P1-15 = 1 Low Water Input
Open @ Low Water
Disable Pre-Charge, Contact Open