Fault
Display
Digital
Inverter
LED
Display*
Contents
Corrective
Actions
Operator
DS
1
(GR)
DS2
(RD)
CPF-00
40
40
Initial
memory
fault
is
Turn
OFF
the
power
supply
once
and
turn
it
ON
again
If
""
I
P11
:
IJ
~
1
detected
.
the
fault
still
exists,
replace
the
inverter
.
CPF-01
Turn
OFF
the
power
supply
,'-
;
"
"
ROM
fault
is
detected
.
once
and
turn
it
ON
again
.
If
the
fault
still
1-1
exists,
replace
the
inverter
.
Record
all
data,
and
then
make
initialization
.
Turn
CPF-04
OFF
the
power
supply
i
i
i
i
C'
-
;
-
^-
"
-0-
Constant
fault
is
once
and
turn
it
ON
again
.
If
the
fault
still
"
,
detected
.
exists,
replace
the
inverter
.
For
initialization
of
constants,
refer
to
Par
.
2
.5
.1
"Constant
Initialization"
on page76
.
CPF-05
Turn
OFF
the
power
supply
-
0
-
-
.,'-
AD
converter
fault
is
once and
turn
it
ON
again
.
If
'-'
detected
.
the
fault
still
exists,
replace
the
inverter
.