2
.
DIGITAL
OPERATOR
(JVOP-114)
(Cont'd)
Protective
Function
Over-
load
Protec-
tion
Motor
Inverter
External
Fault
Signal
Input
Control
Circuit
Fault
t
Error
Causes
Overload,
long
operation
at
low
speed,
improper
V/f
characteristic
setting
.
Motor
rated
current
[constant
(No
.
19)]
setting
is
wrong
.
Over-
Check
the
use
of
machine
.
torque
Motor
current
exceeds
the preset
Correct
the
overload
cause
or
set
Detec-
value
because
of
machine
error
or
a
higher
detection
level
[constant
lion*
overload
.
(No
.
41)]
which
is
within
the
allowable
range
.
External
fault
condition
occurred
.
.
External
nose
Excess
vibration or
shock
Acton
to
be
Taken
Investigate
the
cause
of
over-
load
and
review the
operation
pattern,
V/f
characteristic,
and
motor/inverter
capacities
.
(If
inverter
is
repeatedly
reset
after
an
overload
occurs,
the
inverter
may
fault
.
Investigate
and
correct
the
cause
of
overload
before
restart
.)
.
Set
:
the
rated
current
of
motor
nameplate
value
to
constant
(No
.
19)
.
If
the
above measures
are
not
effective,
lower
the
carver
frequency [constant
(No
43)]
Correct
the
cause
of
the
fault
input
.
Record
all
data
of
C
PF
ii'
then
make
initialization
.
Turn
OFF
power,
then
turn
ON
again
.
If
an
error
is
persistent,
mplace
the
inverter
.
*
For
overtorque
detection (OL3),
fault
display
or
alarm
display
can be
selected
according
to
the
constant
(No
.
40)
setting
.
For
details,
refer
to
"OVERTORQUE
DETECTION
FUNCTION"
on
page 124
.
t
For
details
of
control
circuit faults,
refer
to
Table
1
9
"Details
of
CPF
Display"
on
page
49
.
P,-,
,~,
to
#'
-
'
S
indicate
the
contents
of
digital
operator
display