YASKAWA A1000 - Especificaciones

Busca en linea o descarga Especificaciones para No YASKAWA A1000 -. YASKAWA A1000 - Specifications Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir

Indice de contenidos

Pagina 1 - YASKAWA AC Drive A1000

YASKAWA AC Drive A1000High Performance Vector Control DriveQuick Start GuideMANUAL NO. TOEP C710616 27AType: CIMR-AC Models: 200 V Cla

Pagina 2 - Table of Contents

3 Electrical InstallationYASKAWA ELECTRIC TOEP C710616 27A YASKAWA AC Drive - A1000 Quick Start Guide 9 Wiring Specification Main CircuitUse the f

Pagina 3 -  Safety Warnings

3 Electrical Installation10 YASKAWA ELECTRIC TOEP C710616 27A YASKAWA AC Drive - A1000 Quick Start Guide EMC Filter InstallationThis drive has been

Pagina 4 - Fire Hazard

3 Electrical InstallationYASKAWA ELECTRIC TOEP C710616 27A YASKAWA AC Drive - A1000 Quick Start Guide 11• Use a DC reactor or AC reactor on the inpu

Pagina 5 - Equipment Hazard

3 Electrical Installation12 YASKAWA ELECTRIC TOEP C710616 27A YASKAWA AC Drive - A1000 Quick Start Guide Control Circuit TerminalsThe figure below

Pagina 6

3 Electrical InstallationYASKAWA ELECTRIC TOEP C710616 27A YASKAWA AC Drive - A1000 Quick Start Guide 13NOTICE: The terminals HC, H1, H2 are used fo

Pagina 7 - 2 Mechanical Installation

14 YASKAWA ELECTRIC TOEP C710616 27A YASKAWA AC Drive - A1000 Quick Start Guide4 Keypad Operation4 Keypad Operation Digital Operator and KeysThe dig

Pagina 8 -  IP00/Open-Chassis Drives

4 Keypad OperationYASKAWA ELECTRIC TOEP C710616 27A YASKAWA AC Drive - A1000 Quick Start Guide 15 Menu Structure and ModesThe following illustratio

Pagina 9 - 3 Electrical Installation

16 YASKAWA ELECTRIC TOEP C710616 27A YASKAWA AC Drive - A1000 Quick Start Guide5 Start Up5Start Up Drive Setup ProcedureThe illustration below shows

Pagina 10 - <1>

5 Start UpYASKAWA ELECTRIC TOEP C710616 27A YASKAWA AC Drive - A1000 Quick Start Guide 17 Normal / Heavy Duty Selection (C6-01)The drive supports t

Pagina 11 - Wiring the Main Circuit Input

5 Start Up18 YASKAWA ELECTRIC TOEP C710616 27A YASKAWA AC Drive - A1000 Quick Start GuideFor Auto-Tuning enter the Auto-Tuning menu and perform the

Pagina 12 - Main Circuit Terminals

YASKAWA ELECTRIC TOEP C710616 27A YASKAWA AC Drive - A1000 Quick Start Guide 1Table of Contents1 SAFETY INSTRUCTIONS AND GENERAL WARNINGS . . . . . .

Pagina 13 - Control Circuit Terminals

5 Start UpYASKAWA ELECTRIC TOEP C710616 27A YASKAWA AC Drive - A1000 Quick Start Guide 19 Run Command Selection (b1-02)Set parameter b1-02 accordin

Pagina 14 - 3 Electrical Installation

5 Start Up20 YASKAWA ELECTRIC TOEP C710616 27A YASKAWA AC Drive - A1000 Quick Start Guide Test RunPerform the following steps to start up the machi

Pagina 15 - Keys and Functions

6 Parameter TableYASKAWA ELECTRIC TOEP C710616 27A YASKAWA AC Drive - A1000 Quick Start Guide 216 Parameter TableThis parameter table shows the most

Pagina 16 -  Menu Structure and Modes

6 Parameter Table22 YASKAWA ELECTRIC TOEP C710616 27A YASKAWA AC Drive - A1000 Quick Start Guided1-17Jog Frequency ReferenceSets the Jog frequency r

Pagina 17

6 Parameter TableYASKAWA ELECTRIC TOEP C710616 27A YASKAWA AC Drive - A1000 Quick Start Guide 23H3-14Analog Input Terminal Enable SelectionDetermine

Pagina 18

6 Parameter Table24 YASKAWA ELECTRIC TOEP C710616 27A YASKAWA AC Drive - A1000 Quick Start GuideL3-06Stall Prevention Level during RunEnabled when L

Pagina 19 - CAUTION

6 Parameter TableYASKAWA ELECTRIC TOEP C710616 27A YASKAWA AC Drive - A1000 Quick Start Guide 25U2-10 Torque Reference at Previous FaultU2-11 Input

Pagina 20 - I/O Setup

26 YASKAWA ELECTRIC TOEP C710616 27A YASKAWA AC Drive - A1000 Quick Start Guide7 Troubleshooting7 Troubleshooting General Fault and AlarmsFaults and

Pagina 21 -  Test Run

7 TroubleshootingYASKAWA ELECTRIC TOEP C710616 27A YASKAWA AC Drive - A1000 Quick Start Guide 27Output Phase LossOutput cable is disconnected or th

Pagina 22 - No. Name Description

7 Troubleshooting28 YASKAWA ELECTRIC TOEP C710616 27A YASKAWA AC Drive - A1000 Quick Start Guide Operator Programing ErrorsAn Operator Programming

Pagina 23

2 YASKAWA ELECTRIC TOEP C710616 27A YASKAWA AC Drive - A1000 Quick Start Guide1 Safety Instructions and General Warnings1 Safety Instructions and Gen

Pagina 24

7 TroubleshootingYASKAWA ELECTRIC TOEP C710616 27A YASKAWA AC Drive - A1000 Quick Start Guide 29Current detection error• One or all output phases ar

Pagina 25

30 YASKAWA ELECTRIC TOEP C710616 27A YASKAWA AC Drive - A1000 Quick Start Guide8 Safe Disable Input Function8 Safe Disable Input Function Specificat

Pagina 26

8 Safe Disable Input FunctionYASKAWA ELECTRIC TOEP C710616 27A YASKAWA AC Drive - A1000 Quick Start Guide 31 Disabling and Enabling the Drive Outp

Pagina 27 - 7 Troubleshooting

8 Safe Disable Input Function32 YASKAWA ELECTRIC TOEP C710616 27A YASKAWA AC Drive - A1000 Quick Start GuideSafe Disable Status MonitorWith the Safe

Pagina 28 - 7 Troubleshooting

Revision HistoryThe revision dates and the numbers of the revised manuals appear on the bottom of the back cover. Date of Publication Rev. No. Section

Pagina 30

英文 No.6-5 (A4) YEG向けインバータ製品用YASKAWA ELECTRIC CORPORATIONIn the event that the end user of this product is to be the military and said product is to be

Pagina 31 - Safe Disable Circuit

1 Safety Instructions and General WarningsYASKAWA ELECTRIC TOEP C710616 27A YASKAWA AC Drive - A1000 Quick Start Guide 3Do not touch any terminals b

Pagina 32 - Power Module

1 Safety Instructions and General Warnings4 YASKAWA ELECTRIC TOEP C710616 27A YASKAWA AC Drive - A1000 Quick Start GuideCAUTION Crush HazardDo not c

Pagina 33 - Digital Operator Display

1 Safety Instructions and General WarningsYASKAWA ELECTRIC TOEP C710616 27A YASKAWA AC Drive - A1000 Quick Start Guide 5 Precautions for CE Low Vol

Pagina 34 - October 2008 −−First edition

6 YASKAWA ELECTRIC TOEP C710616 27A YASKAWA AC Drive - A1000 Quick Start Guide2 Mechanical Installation2 Mechanical Installation Upon ReceiptPlease

Pagina 35

2 Mechanical InstallationYASKAWA ELECTRIC TOEP C710616 27A YASKAWA AC Drive - A1000 Quick Start Guide 7 Dimensions IP20/NEMA Type 1 DrivesNote: IP

Pagina 36

8 YASKAWA ELECTRIC TOEP C710616 27A YASKAWA AC Drive - A1000 Quick Start Guide3 Electrical Installation3 Electrical InstallationThe figure below show

Comentarios a estos manuales

Sin comentarios