YASKAWA SERVO Manual de usuario Pagina 201

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 239
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 200
9.3 Troubleshooting Malfunction Based on Operation and Conditions
9-29
9
Troubleshooting
Servomotor
Overheated
Ambient operating temperature is
too high.
Measure the linear servomotor
ambient operating temperature.
Reduce the ambient operating tem-
perature to 40°C max.
Linear servomotor surface is dirty. Check visually.
Clean dust and oil from linear ser-
vomotor surface.
Linear servomotor overloaded Check the load status with monitor.
If overloaded, reduce load or
replace with larger capacity SER-
VOPACK and linear servomotor.
Polarity detection is not performed
correctly.
Check if the value of Un004 (Elec-
tric Angle 2) at an arbitrary position
is between ±10 degrees.
Correct the settings for the polarity
detection related parameter.
(cont’d)
Problem Probable Cause Investigative Actions Corrective Actions
Vista de pagina 200
1 2 ... 196 197 198 199 200 201 202 203 204 205 206 ... 238 239

Comentarios a estos manuales

Sin comentarios