Yaskawa SmartTrac Fault Tables Manual de usuario Pagina 2

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 66
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 1
10/17/00
New Berlin
Technology Center
Smart Trac
Product Development
Design
Document
Faults.doc
Rev. # 19 Page 1 of 64
Title: Fault Declarations
The information contained in this document is the CONFIDENTIAL property of MagneTek Inc.
File = N:\PROJECT\515\SmartTrac\DOCS\Faults.DOC Print Date: 10/17/00
1
REV DATE NAME DESCRIPTION
0 04/23/98 J. Muszynski Original.
1 08/21/98 D. W. Karraker Split driver fault codes among known I/O drivers. Added sub-heading listing DPRAM faults.
2 12/04/98 D. W. Karraker Updated DPRAM and PCU faults
3 12/04/98 M. DuVal Added faults for PG-SC. Added cross reference column as to the actual error number shown in Smart Trac
Workstation SW
4 01/26/99 J. Cretney Added displayed fault codes to fault # 30016 through 30047
5 02/27/99 M. DuVal Added Smart Trac LAN fault table.
6 03/05/99 J. Cretney Merged C-Function Block Fault descriptions. Added decimal representation of fault codes.
7 03/22/99 M. DuVal Added more Smart Trac LAN fault codes.
8 03/23/99 T. Wiese Change LAN allocation errors from output to I/O
9 08/04/99 M. DuVal Added Operating System faults, Fault Range Map, and Document Revision. Removed unused sections. Reformatted
fault tables. Corrected documentation errors.
10 08/18/99 M. DuVal Include revisions from document design review. Added columns: Corrective Action and Assign Program Inputs.
11 09/10/99 T. Ellis Changed Assign Program Inputs to reflect correct values. Provided information for Corrective Actions. Document
clarification and corrections.
12 12/16/99 S. Mack Added new faults being declared by Function Blocks in MAG_WIND_V1_9 and MAG_STD_V1_9. Added to the
explanations of fault types.
13 12/20/99 D. W. Karraker Added individual CPF and OPE faults under Inverter Faults
14 01/05/00 M. DuVal Renamed references of MAG_CPB_V1_9 to MAG_STD_V1_9. Revised fault definitions in Function Blocks section
specific to MAG_STD_V1_9 library.
15 01/11/00 D. W. Karraker Added revision number for DPRAM driver to section 1.2
16 01/12/00 M. DuVal Minor changes to Function Blocks section.
17 01/31/00 D. W. Karraker Added inverter alarm codes
18 04/03/00 J. Nickel Added 2 fields to each fault code to indicate which list(s) the fault will be placed in by default: OLDEST or NEWEST.
Also added a column to indicate if the fault is considered a PRIORITY fault by default. Changed the description of
fault #77643 (CAVE Input). Changed legends of event codes 95736-95755 to include “Alm:”. Revised many of the
Corrective actions which were labeled ‘Consult Factory’. Added faults 12B08 – 12B0B, & 12B67. These are new
input faults for the DIAM_2, INRT_1, CTCW_0, CTCW_1 and POSR_0 blocks. Corrected some other typos in the
document. Added another Program Input called ‘FB_Setup’ for use to designate improper inputs to various block
inputs.
19 05/09/00 S. Mack DIAM_0 can declare NO_SYSTEM_CLOCK fault. DIAM_2 will declare DIAM_2_INPUT faults if sanity checks are
exceeded for NumberCalculation, RatedLineSpeed, S_RPM_at_M_RPM, MinDiameter, and MaxDiameter. Updated
Fault Document Revisions.